引用本文: |
-
蔡东方,袁爱萍,覃然,唐艳霞,汪静玲.高频红外吸收法测定锑精矿中的硫含量[J].广西科学院学报,2006,22(S1):437-438,440. [点击复制]
- CAI Dong-fang,YUAN Ai-ping,QIN Ran,TANG Yan-xia,WANG Jing-ling.Determination of Sulfur in Antimony Concentrate by the High Frequency IR-absorption Spectrometry[J].Journal of Guangxi Academy of Sciences,2006,22(S1):437-438,440. [点击复制]
|
|
摘要: |
采用高频红外吸收法测定硫化锑精矿和氧化锑精矿中的硫含量。确定出最佳分析条件是用1.50g钨粒+0.50g锡粒+0.60g纯铁作助溶剂。硫化锑精矿称样量为0.00500g,氧化锑精矿称样量为0.20000g,分析时间以65s较为适宜。RSD(硫化锑)=1.31%(n=8),RSD(氧化锑)=2.03%(n=8)。 |
关键词: 高频红外吸收 硫 锑精矿 |
DOI: |
投稿时间:2006-08-12 |
基金项目:国家质检总局科研项目(2004IK079)内容之一;广西大型仪器网资助 |
|
Determination of Sulfur in Antimony Concentrate by the High Frequency IR-absorption Spectrometry |
CAI Dong-fang, YUAN Ai-ping, QIN Ran, TANG Yan-xia, WANG Jing-ling
|
(Guangxi Entry-Exit Inspection and Quarantion Bureau, Nanning, Guangxi, 530021, China) |
Abstract: |
The method of high frequency IR-absorption spectrometry used to determine the sulfur in antimony sulfide concentrates and antimony oxide concentrates is introduced in this article.By this method the best analytical conditions determined are that the dosage of flux is 1.50g of tungsten granular、0.50 g of tin granular and 0.60g of pur iron filings,the sample weight of antimony sulfide concentrates and antimony oxide concentrates is 0.00500g and 0.20000g,the analysis time is 65s.The relative standard deviation of antimony sulfide concentrates and antimony oxide concentrates was 1.31% and 2.03%(n=8). |
Key words: high frequency IR-absorption spectrometry sulfur antimony concentrate |